  Datasheet File OCR Text:
  ferrite devices contents 15-1 vol. 1 sales offices: visit our web site at http://www.temex.net contents contents circula tors and isola tors specific request . . . . . . . . . . . . . . . . . . 15-2 technical informa tion . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15-3 drop-in circula tors & isola tors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15-9 coaxial devices . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15-19 w a veguide devices . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15-34 design aid . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15-50 how to order? . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15-56 quality assurance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15-57 page ferrite devices spirit of new technology all speci?ations contained in that catalog are subject to change without notice.
ferrite devices speci?c request 15-2 vol. 1 sales offices: visit our web site at http://www.temex.net circulator and isolator specific request environmental conditions space ? military ? commercial ? airborne ? naval ? ? coaxial ? waveguide waveguide reference: connectors (or ?anges) and terminations port # 1: port # 3: port # 2: port # 4: technology (drop-in, waveguide, etc.) : part number (if existing) : operating frequency : package/dimensions : input power (cw/peak) : reverse power for isolator (cw/peak) : insertion loss : db isolation : db v.s.w.r. operating temperature range : c port configuration please, indicate the direction of circulation (outline): isolator circulator please fax this sheet to the sales office it may concern fm: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . company: . . . . . . . . . . . . . . . . . . . . . . . . . . . phone: . . . . . . . . . . . . . . . . . . . . . . . . . . . . fax: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . to:temex attention of m.: . . . . . . . . . . . . . . . . . . . . . . . comments: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
technical information technology y-junction circulator the y-junction exists in three main technologies: ? coaxial devices : these feature triplate technology with coaxial connectors. ? drop-in circulator s : in triplate or microstrip technology. ? w aveguide devices : it consist of three waveguides forming an h-plane junction in either a "t" or a "y"-symmetrical structure. when very high power is needed, the technology uses a four-port differential phase shift duplexer. the y-junction circulator uses spinel fer rites or g arnet fer rites in the presence of a magnetic bias ?eld, to provide a non-reciprocal effect. a 3-port circulator (shown in ?gure 1) is the basic model, which can be used to explain how it operates. if a signal is applied at port # 1, it will emerge from port # 2 with a loss characteristic called insertion loss . typical values of insertion loss: 0.1 to 0.5 db. in the reverse direction, there will be leakage at port # 3 from the incoming signal at port # 1. this leakage called isolation is typically 20 db below incoming power at port # 1. due to the 3rd order symmetry of the y-junction, the behavior is the same for the other ports, with respect to port # 1 to port # 2, port # 2 to port # 3 and port # 3 to port # 1. the circulator's role is to pass energy, for instance, in the rf-head of a radar, assuring high isolation between the high power transmitter and the sensitive low power receiver ( ? gure 2 ). fig. 1 fig. 3 fig. 2 port 1 port 2 port 3 antenna power source load mismatch circulator receiver isolator transmitter ~ ferrite devices technical information /technology 15-3 vol. 1 sales offices: visit our web site at http://www.temex.net
ferrite devices technical information / technology 15-4 vol. 1 sales offices: visit our web site at http://www.temex.net a y-junction circulator can be made into an isolator by adding an internal termination on port # 3, for example. the device passes signals with low loss (port # 1 to port # 2) and with high loss in the opposite direction. it is used to "isolate" one microwave device from another. it can, for example, protect expensive, high-power rf sources from variations in loading conditions or mismatching ( see ? gure 3 ). 4-port differential phase shift circulator this four-port-device is normally used with one load, such as a high-power circulator (duplexer), or with two dummy loads, such as a high-power isolator. this circulator consists of three basic parts: ? hybrid folded magic tee ? twin parallel ferrite phase shift sections ? 3 db coupler resonance isolator - waveguide devices by magnetically biasing a ferrite inside a waveguide, the non-reciprocal effect is obtained: with low losses in one direction and high losses (isolation) in the opposite direction. those isolators are only used for low and medium power (see ?gure 4). the ferrite material has to dissipate the return power due to mismatch. fig. 4 fig. 5 ho waveguide magnet magnet ferrite material 3 port port 2 port 4 3 db hybrid coupler 1/2 differential celles folded magic tee port 1 4 port differential phase shift circulator ferrite switches these devices change the polarity of the magnetic bias (n s) and the rf-signal direction of circulation. this is made by a coil instead of a magnet. this technology is used for ferrite switches in both product lines: ? y-junction ? 4-port differential phase shift device
ferrite devices technical information / electrical features 15-5 vol. 1 sales offices: visit our web site at http://www.temex.net typical values: 0.1 to 0.4 db. isolation for an isolator: if a signal is applied at port # 2, it will emerge from port # 1 with a high insertion loss called isolation, which is also expressed in db (ratio of the output signal to the input signal). for a circulator: for a circulator, it should be noted that this parameter is not applicable. but it is common to use this parameter as if the circulator could be made into an isolator by terminating one port (e.g. port # 3) with a matched load. the isolation measured is dependent on the vswr of both the termination and the circulator port. typical values: -20 to -30 db electrical features all the parameters given in this section (insertion loss, isolation, vswr, power) are absolute maximum ratings assured in the operating temperature range. typical values are obviously better. insertion loss (i.l.) if a signal is applied at port # 1, it will emerge from port # 2 with a loss characteristic called insertion loss, which will be the ratio of the output signal to the input signal expressed in db: i.l db = 10 log 10 p in p out [] vswr the re?ection coefficient magnitude characterizes the re?ective property of each port of an isolator or circulator (see fig. 6). it is useful to use the voltage standing wave ratio (vswr) ?? ?? p reff p in = dut vswr = ?? ?? 1 + 1 C ~ p in p reff p out typical values: 1.07: 1 to 1.25: 1 fig. 6
ferrite devices technical information / electrical features 15-6 vol. 1 sales offices: visit our web site at http://www.temex.net effect of an isolator on vswr (fig.7) fig. 7 the effective input vswr of an isolator will vary at a function of the load vswr. if the output load mismatch is increased, energy is re?ected at the termination port, attenuated by the isolation and then re?ected back to the input. this effect increases the total input vswr observed at the input. example: the load vswr is 10: 1, the isolator has 18 db isolation, which improves the input vswr to 1.20: 1. temperature range the performance of a circulator or isolator is limited by ferrite and magnet material behavior in the operating temperature range. in this catalog, for each device the main speci?cations are given: ? at room temperature: 25 c, ? over a speci?ed temperature range. power rating the input power to a ferrite device can be supplied from a cw or a pulsed source. for pulsed source, peak and average power should be speci?ed, pulse duration and duty cycle are also needed in order to determine an adequate safety margin. average power for high power products, average power is limited by the dissipation in the ferrite. adequate cooling is necessary to insure the ferrite material does not reach excessive temperature. there are three kinds of cooling: liquid, forced air or natural convection. peak power to avoid breakdown or arcing, special ferrite materials are designed. frequency of operation and peak-power level determine whether the waveguide circulator should be pressurized or unpressurized with dry air or gas (n 2 or sf 6 ). isolator load ~ input vwsr source
load vswr power rating of a ferrite device depends on the mismatch at the output port (load vswr); for instance, for an isolator, if load vswr is 2: 1, more than 10% of the input power is re?ected inside the ferrite device to the internal load. in case of short-circuit (in?nite load vswr), the ferrite device has to handle the equivalent of twice the input cw-power, and the equivalent of a peak power equal to 4 times the input power, based on the higher internal voltage levels. therefore, the time-duration of short circuit or high load vswr is needed in order to determine an adequate safety margin. third order intermodulation products (imp 32 ) harmonics and third order intermodulation products appear when non-linear elements are used such as ferrite materials, metal welds, surface ?nish, etc. when two tones - f 1 and f 2 - are applied to a ferrite device, the relative amplitudes of 2f 1 - f 2 and 2f 2 -f 1 are critical in some communication systems and should be speci?ed when ordering (see fig. 8). ? test conditions (to be speci?ed) -f 1 and f 2, -p 1 and p 2 in w or dbm. ? third order intermodulation products -p im3 in dbm or, - imp 32 = p im3 - p 1 in dbc. fig. 8 power p1 p2 f 1 f 2 imp 32 p im3 2f 1 - f 2 ? f 2f 2 - f 1 frequency ferrite devices technical information / electrical features 15-7 vol. 1 sales offices: visit our web site at http://www.temex.net
ferrite devices technical information / electrical features 15-8 vol. 1 sales offices: visit our web site at http://www.temex.net intermodulation parameters base stations are using modulation signal that temex may not have. in order to design and to provide data about intermodulation level 3, temex is using a two tones (channels) measurement. the following conditions are used for the measurements: ? 1. power on each channel: de?ned by the customer or minimum 25 watt if not speci?ed. frequencies of each two tones: taken at the center of the bandwidth ? 2. forward intermodulation f1, p1, f2, p2, as input signals will give a forward intermodulation level imp3 ? 3. reverse intermodulation f1, p1 in input, f2, p2 at the output, as input signals will give a reverse intermodulation level imp3 ? 4. f1 and f2 are two tones with 20 mhz difference test set up high band: 2090 mhz diplexer 1ton power 44.5 dbm dut diplexer tx path cable load rx path spectrum analyser 3rd imd frequency: 2117.5 mhz low band: 2080 mhz
drop-in circulators & isolators selection guide 15-9 vol. 1 drop-in circulators & isolators selection guide p a ge intr oduction 15-1 0 high po wer subminia ture smd isola t or s 15-1 1 - frequenc y range: 370 - 470 mh z ; size 1 0 x 1 0 15-12 80 0 - 90 0 mh z ; size 1 0 x 1 0 15-12 1 80 0 - 1 90 0 mh z ; size 1 0 x 1 0 15-12 high po wer wide band subminia ture smd isola t or s - frequenc y range: 370 - 470 mh z ; size 12 x 12 15-13 minia turized dr op -in isola t or s & cir cula t or s 15-14 sales offices: visit our web site at http://www.temex.net
drop-in circulators & isolators introduction 15-10 vol. 1 sales offices: visit our web site at http://www.temex.net introduction for more than 10 years, temex designs miniaturized drop-in circulators and isolators. today, patented designs, space quali?ed drop-in assemblies and time proven circulators and isolators are available. current production of drop-in devices is covering frequency ranges from hf, vhf, uhf and up to 18 ghz. new technologies of drop-in devices have been developed these last years: - patented designs with magnetical and electrical shieldings, - wide band devices, - operating with various substrates, - integrated substrates, - double cell circulator designs, - integrated functions (diode limitors, etc.), - low mass sub-systems for satellite pay-load integration, - technological process (smd & micro-electronic applications mmic compatible). automated brazing benches, cycling and ageing benches, s-parameters networks analyzers with automated test benches are the basic tools used by temex for mass production capacity. in addition, test set-up for 3rd order intermodulation products for vhf/uhf frequency bands, power handling capability and clean room for space components and assemblies are available in our facility. custom components temex capability has broadened to custom sub-systems which integrate circulators, terminations, limitors, detectors, etc. furthermore, the following presentation of some products is only a resume of our expertise and our engineering staff stands ready to design and produce custom components to state-of-art speci?ation.
drop-in circulators & isolators high power subminiature smd isolators 15-11 vol. 1 sales offices: visit our web site at http://www.temex.net high power subminiature smd isolators description temex surface mount isolators, designed for cellular applications, with high performance at low cost. these designs are suitable for ir re?ow assembly at 235 c. delivered in tape and reel, they are available at the main cellular frequency band. reel of 500 pieces are delivered in sealed pack with p/n and date code. custom product are available upon request. outline drawings cw ccw
drop-in circulators & isolators high power subminiature smd isolators 15-12 vol. 1 sales offices: visit our web site at http://www.temex.net ub11xx ; ub12xx parameters units frequency bandwidth 10 20 30 478 - 484 380 - 400 370 - 400 available frequency range mhz 410 - 420 410 - 433 410 - 440 450 - 470 isolation db 15 13 10 insertion loss db 0.8 1.0 1.25 return loss db 15 13 10 ud11xx ; ud12xx parameters units -20 to +70 c min. max. custom frequency bandwidth mhz 5 20 isolation db 15 insertion loss db 0.9 return loss db 15 forwarder power (1) watts 10 reverse power (2) watts 3 frequency range 370 - 470 mhz ; size 10 x 10 mm ub11xx (clock wise) and ub12xx (counterclock wize) series features ? typical: 15 db isolation, 0.8 db insertion loss ? low cost product frequency range 800 - 900 mhz ; size 10 x 10 mm uc11xx (clock wise) and uc12xx (counterclock wize) series features ? typical: 18 db isolation, 0.5 db insertion loss ? input power 10 w-cw ? low cost product ? available in tape and reel frequency range 1800 - 1900 mhz ; size 10 x 10 mm ud11xx (clock wise) and ud12xx (counterclock wize) series features ? typical: 18 db isolation, 0.6 db insertion loss ? available frequency bands: ? low cost product 1710 - 1780 mhz 1805 - 1880 mhz 1850 - 1980 mhz 1930 - 1990 mhz cw p/n ccw p/n frequency (mhz) uc1134-08 uc1234-08 819-854 uc1130-01 uc1230-01 869-894 uc1134-06 uc1234-06 880-915 uc1134-12 ud1234-12 885-920 uc1134-00 uc1234-00 925-960 uc11xx ; uc12xx parameters units -40 to +85 c min. max. custom frequency bandwidth mhz 5 20 isolation db 15 insertion loss db 0.7 return loss db 14 forwarder power watts 10 reverse power (1) watts 3 (1) continuous power during 2 mn electrical speci?ations performance warranted over temperature range: -20, +70 c (1) continuous power (2) continuous power during 2 mn performance warranted over temperature range: -20, +70 c
drop-in circulators & isolators high power wide band subminiature smd isolators 15-13 vol. 1 sales offices: visit our web site at http://www.temex.net ub114x ; ub124x parameters units min. max. isolation db 10 insertion loss db 1.15 return loss db 10 forwarder power (1) watts 10 reverse power (2) watts 3 performance warranted over temperature range: -20, +70 c (1) continuous power (2) continuous power during 2 mn high power wide band subminiature smd isolators description temex surface mount isolators, designed for cellular applications, with high performance at low cost. these designs are suitable for ir re?ow assembly at 235 c. delivered in tape and reel, they are available at the main cellular frequency band. reel of 500 pieces are delivered in sealed pack with p/n and date code. custom product are available upon request. outline drawings frequency range 370 - 470 mhz ; size 12 x 12 mm ub11xx (clock wise) and ub12xx (counterclock wize) series features ? typical: 12 db isolation, 1 db insertion loss ? low cost product ? broadband product: 50 mhz
drop-in circulators & isolators miniaturized drop-in circulators & isolators 15-14 vol. 1 sales offices: visit our web site at http://www.temex.net temex has designed a line of miniaturized drop-in circulators and isolators covering the frequency ranges from 75 mhz to 18 ghz . these circulators and isolators are designed to be used for applications where space saving and magnetic shielding are required, to avoid any detuning when operating close to magnetic ?ld or ferrous materials: - cellular applications such as nmt , amps , ct-1 , ct-2 , tacs , e-tacs , gsm , jdc , dect , dcs , pcs, wlan and any communication base stations: tfts , inmarsat etc . - broadcasting applications: dab , etc. - microstrip sub-systems - airborne equipment - missiles - radars / phase array antennas - satellite pay loads - earth stations circulators and isolators are available under standard packages with ?tandard inch?dimensions. isolators integrate the load which is: up to 60 w-cw power handling capability for vhf/uhf bands, 1 w-cw power handling capability for microwave frequency bands. for microwave applications, circulators are available in round package. isolators are available in ?nge type package with or without through mounting holes. depending on the requested isolation, one or two cell designs are available in the vhf/uhf band as standard packages. the drop-in design allows easy and fast installation into stripline and microstrip assemblies with mounting screws or soldering with conductive epoxy glue. test jigs for different packages are available for customers incoming inspection. miniaturized drop-in circulators & isolators 3 2 lc3201-01 n xxx 1 nda110-02 3 2 n xxx 4 1
drop-in circulators & isolators miniaturized drop-in circulators & isolators 15-15 vol. 1 sales offices: visit our web site at http://www.temex.net 3-port circulators & isolators model frequency isolation insertion v.s.w.r. power case operating range (db) loss (db) (w-cw) temperature circulator isolator (mhz) typ. min. typ. max. max. input load* c nb3040 nb1040 380-430 22 20 0.3 0.4 100 60 t58 -10 to +55 nc3104 nc1104 890-960 23 20 0.3 0.4 1.25 100 60 t42 -10 to +55 nc3106 nc1106 920-960 25 20 0.3 0.4 1.25 100 60 t42 -10 to +55 nd3100 nd1100 1030-1090 22 20 0.3 0.5 1.25 100 10 t42 -10 to +55 nd3141 nd1141 1270-1400 22 20 0.3 0.5 1.25 30 3 t42 -10 to +55 nd3161 nd1161 1452-1492 22 20 0.3 0.4 1.25 30 0.3 t42 -10 to +55 nd3162 nd1162 1525-1661 22 20 0.3 0.5 1.25 30 3 t42 -10 to +55 nd3183 nd1183 1710-1785 22 20 0.3 0.4 1.25 30 3 t44 -10 to +55 nd3184 nd1184 1805-1880 22 20 0.3 0.4 1.25 50 50 t44 -10 to +55 nd3181 nd1181 1805-1880 23 20 0.3 0.4 1.25 50 50 t42 -10 to +55 nd3186 nd1186 1930-1990 23 20 0.3 0.4 1.25 50 50 t44 -10 to +55 nd3182 nd1182 1930-1990 23 20 0.3 0.4 1.25 50 50 t42 -10 to +55 ne1101 2100-2300 23 20 0.3 0.4 1.25 10 1 t44 -10 to +55 ne1120 2300-2500 23 20 0.3 0.4 1.25 10 1 t44 -10 to +55 ne1130 2700-2900 23 20 0.3 0.4 1.25 150 15 t44 -30 to +70 nf1100 2700-3100 23 20 0.4 0.5 1.3 150 15 t44 -30 to +70 ng3142 5400 - 5900 22 20 0.3 0.4 1.22 1 1 t53 -30 to +70 ng3140 ng1140 5650 - 5850 25 23 0.3 0.4 1.25 10 1 t45 -30 to +70 nj1101 7900 - 8400 20 17 0.5 0.6 1.50 10 1 nj1 -40 to +85 nj1111 8500 - 9500 20 17 0.6 0.7 1.50 10 1 nj1 -40 to +85 nj1139 9820- 12600 18 16 0.6 0.7 1.45 1 1 nj1 -40 to +85 nj3130 11000- 11500 22 20 0.4 0.5 1.25 20 nj3 -40 to +85 nj3151 13000- 14000 22 20 0.4 0.5 1.25 30 nj3 -40 to +90 nj1140 13000- 14000 22 20 0.6 0.8 1.50 10 2 nj1 -45 to +125 nj1161 14000- 14500 22 20 0.5 0.6 1.25 20 1 nj1 -45 to +125 nj1162 14500- 15500 22 20 0.5 0.6 1.50 10 1 nj1 -40 to +85 nj1160 15500 - 16000 22 20 0.5 0.6 1.50 10 1 nj1 -40 to +85 * notes: ? for an isolator: power of the integrated load, 10 w-load optional, ? for a circulator: re?ected power handling capability.
drop-in circulators & isolators miniaturized drop-in circulators & isolators 15-16 vol. 1 sales offices: visit our web site at http://www.temex.net l a b d c w a/2 4x through holes circulator 0,64 .025 n xxx l a b d c w 4x through holes circulator 0,64 .025 n xxx h g e f 1.78 070 0.1 .004 t42 25.4 circ.: 25.4 7.62 20.83 20.83 15.36 7.75 3.81 0.64 1.78 2.1 iso.: 31.75 max. t44 19.05 circ.: 19.05 6.35 14.50 14.50 10.57 6.20 3.13 0.64 1.78 2.03 iso.: max. 25.4 t45 12.7 circ.: 12.7 6.35 9.65 9.65 6.85 4.32 3 0.63 1.8 1.9 or iso.: max. 12.7 m2.5 t54 51.5 51.5 12 41.8 41.8 34.15 12.5 3.5 2 1.75 3.3 iso.: max. 51.5 m2.5 t58 51 51 19 42 42 34 12.5 4.2 0.5 7 3.5 iso.: max. 51 outline drawings 3-port circulators & isolators dimensions in mm t42 - t44 - t45 - t54 - t58 series case l w h a b c d e f g holes
drop-in circulators & isolators miniaturized drop-in circulators & isolators 15-17 vol. 1 sales offices: visit our web site at http://www.temex.net bb xxxx-xx n xxx 47.51 1.870 2 3 .118 45 1.722 2.5 .098 15 .591 25 984 50 0.25 1.969 010 t50 series ba1032-xx n ? bts 2 trs. 3 d ? bts 20 5 t52 series 9.52 0 120 t53 series 1 .039 4.6 .181 max 1.7 2.2 + 0.1 0 .098 + .020 - .039 2.5 + 0.5 - 1 .087 + .004 - .000 nj1-series 120 6.35 0 -0.05 250 + 000 - 002 l = 0.5 020 1.27 nj3-series 1.58 54.1 5.4 34.75 6 e 3.5 t0 series
drop-in circulators & isolators miniaturized drop-in circulators & isolators 15-18 vol. 1 sales offices: visit our web site at http://www.temex.net case l w h a b c d e f g holes p42 50.8 25.40 7.62 46.23 20.83 15.36 7.75 3.81 3.81 3.81 2.1 p44 38.1 19.05 6.35 33.50 14.50 10.57 6.35 2.00 2.00 2.00 2.5 nc4112 920-960 46 40 0.4 0.7 1.20 1.25 100 p55 -10 to +55 c nc4116 920-960 46 40 0.4 0.7 1.20 1.25 100 p42 -10 to +55 c nd4112 1805-1880* 46 40 0.4 0.7 1.20 1.25 100 p55 -10 to +55 c nd4224 1805-1880* 46 40 0.4 0.7 1.20 1.25 100 p44 -10 to +55 c nd4117 1805-1880* 46 40 0.4 0.7 1.20 1.25 100 p42 -10 to +55 c *also available in 1930-1990 mhz band. customized devices available 4-port circulators model frequency isolation insertion v.s.w.r. power case operating range (db) loss (db) (w-cw) temperature circulator (mhz) typ. min typ. max typ. max input dimensions in mm 3 2 n?xx 4 1 4 x holes b l a w 0.64 .025 d c h g e f 1.78 .070 0.1 .004 p42 - p44 series p55 series (all fixation holes) how to order? please specify: ? model number, ? center frequency and desired bandwidth, or frequency range, ? direction of circulation (clockwise or counter clockwise). test jig drop-in miniaturized circulators and isolators are measured in custom designed test jigs, in order to simulate operating environmental conditions. special customer application and environmental details must be speci?d when ordering, to avoid correlation problems between temex tests and customer results.temex test jig is recommended to verify product performances. outline drawings
coaxial devices selection guide 15-19 vol. 1 sales offices: visit our web site at http://www.temex.net selection guide page vhf/uhf co axial cir cula t or s & isola t or s 15-20 l o w cos t 15-22 s t and ard 15-23 p a cka ges 3-por t 15-24 p a cka ges 4-por t 15-26 s t and ard co axial devices 1 t o 1 8 gh z 15-28 p a cka ges 15-31 connect or s & t abs 15-33 new ! coaxial devices
coaxial devices vhf / uhf coaxial circulators & isolators 15-20 vol. 1 sales offices: visit our web site at http://www.temex.net coaxial technology waveguide technology 100 10 1 1 10 100 0.1 frequency ghz vhf-uhf average power kw vhf / uhf coaxial circulators & isolators
coaxial devices vhf / uhf coaxial circulators & isolators standard cases versus frequency 3-port-vhf/uhf coaxial circulator/isolator 3-port power devices designed for the wide-band application in the 170 to 1215 mhz frequency range, temex power circulators provide low insertion loss and high isolation. they are speci?ally designed to feature low 3rd order inter- modulation products with power up to 2000 w-cw. they are suitable for telecommunication and broadcasting applications. in order to improve isolation, four-port circulators and isolators are produced by optimally integrating two single-junction circulators in a single package. the insertion loss of four-port circulators includes two pass-through ferrite junctions. they are typically used in telecommuni- cations and radio-telephone applications. options such as con?uration, frequency range, connector type and location, tab (drop-in) con?uration, wider temperature range, high power, etc., are available upon request . temex supplies a wide range of coaxial hf/vhf and uhf circulators covering the frequency range down to 27 mhz. temex uses only in-house produced fer rite materials and therefore offers state-of-the-art features such as low-insertion loss, high isolation in various rugged and space saving packages : the ? series is our standard design for three port junctions. circulators are equipped with kmr/sma connectors and isolators with an internal load of 1 w average/60 w peak, n female connectors for input power higher than 60 w-cw. wide-band ferrite device, such as those in the package, enables coverage of the 225 - 400 mhz band for high power up to 300 w-cw/1 kw peak. new low cost coaxial devices have been specially designed for cellular base stations. case of circulators and isolators are made with aluminum casting in order to drastically reduce cost and deliveries. 100 pa po p2 p4 200 300 400 500 600 700 800 900 1000 110 0 1200 1300 1400 1500 1600 1700 1800 1900 2000 mhz 870 2000 350 1400 210 30 30 100 4-port-vhf/uhf coaxial circulator/isolator 100 ta to t2 td t3 200 300 400 500 600 700 800 900 1000 110 0 1200 1300 1400 1500 1600 1700 1800 1900 2000 mhz 1400 350 760 960 800 1215 235 230 230 225 225 400 400 170 170 30 30 100 ? ? 1 2 225 400 3 general description low cost coaxial devices new ! 15-21 vol. 1 sales offices: visit our web site at http://www.temex.net
coaxial devices vhf / uhf coaxial circulators & isolators frequency average speci?ation in temp. range temperature outline connector type range power isolation inser. loss vswr range drawing female (mhz) max. w min. db max. db max ? bb4110 380 - 430 100 45 0.8 1.25 -10 to +55 p2 n bb4111 406 - 470 100 40 0.8 1.25 -10 to +55 p2 n bb4112 424 - 428 100 50 0.5 1.25 -10 to +55 p2 n bb4113 460 - 468 100 50 0.5 1.25 -10 to +55 p2 n BB4003 470 - 600 50 35 1.1 1.30 -10 to +55 p2 n bc4107 870 - 960 50 45 0.7 1.25 -10 to +55 p4 n bc4108 917 - 960 65 50 0.5 1.20 -10 to +55 p4 n bc4109 935 - 960 65 50 0.5 1.20 -10 to +55 p4 n customized devices available for more 50 w-cw input power, cooling is necessary by conduction via heat sink (r th = 0.4 c / w max) 15-22 vol. 1 sales offices: visit our web site at http://www.temex.net new ! how to order? please specify: ? model number, ? center frequency and desired bandwidth, or frequency range, ? direction of circulation (clockwise or counter clockwise). low cost coaxial circulators & isolators 3-port circulators & isolators 4-port circulators & isolators frequency average speci?ation in temp. range temperature outline connector circulator isolator range power isolation inser. loss vswr range drawing female (mhz) max. w min. db max. db max ? bc3062 bc1062 920 - 960 50 20 0.4 1.25 -10 to +55 t15 n bc3060 bc1060 920 - 960 50 20 0.4 1.25 -10 to + 55 t12 sma bc3080 bc1080 920 - 960 60 23 0.3 1.25 -10 to + 55 t59 n bd3067 bd1067 1805 - 1880* 50 20 0.3 1.20 -10 to + 55 t12 sma bd1062 bd3062 1805 - 1880* 50 20 0.3 1.20 -10 to + 55 t15 n be1070 be3070 2100 - 2180 50 23 0.3 1.20 -10 to + 55 t12 sma * available in 1930 - 1990 mhz band sma female sma female sma female t15 t59
coaxial devices vhf / uhf coaxial circulators & isolators frequency range avg. peak speci?ations at 25 c spec. in temperature range temperature outline connector type (mhz) power power isolation inse. loss vswr isolation inse. loss vswr range drawing (female) max. w max. kw min. db max. db max. min. db max. db max. ? frequency range avg. peak speci?ations at 25 c spec. in temperature range temperature outline connector circulator isolator (mhz) power power isolation inse. loss vswr isolation inse. loss vswr range drawing (female) max. w max. kw min. db max. db max. min. db max. db max. ? ba3038 27 60 15 1.0 1.40 15 1.0 1.40 -40 to +70 t0 n (3) ba3011 ba1011 62-72 20 18 0.8 1.30 17 1 1.35 -10 to +55 t0 sma ba3021 68-88 100 18 0.8 1.30 17 1 1.35 -10 to +55 t0 n (3) ba3015 ba1015 72-88 50 18 0.8 1.30 17 1 1.35 -10 to +55 t0 sma ba3010 ba1010 88-108 100 18 0.8 1.30 17 1 1.35 -10 to +55 t0 n (3) ba3012 ba1012 105-145 50 18 0.8 1.30 16 1 1.40 -10 to +55 t0 sma ba3040 138-155 250 23 0.35 1.20 22 0.4 1.25 0 to +70 t0 n (3) ba3013 155-174 250 23 0.35 1.20 22 0.4 1.25 0 to +70 t0 n (3) ba3016 ba1016 165-200 100 18 0.8 1.30 17 1 1.35 -10 to +55 t0 n (3) ba3029 174-225 100 18 0.8 1.30 17 1 1.35 -10 to +55 t0 n (3) ba3017 ba1017 200-235 100 18 0.8 1.30 17 1 1.35 -10 to +55 t0 n (3) ba3017 216-230 250 1.00 32 0.3 1.12 30 0.5 1.15 +20 to +70 t0 n (3) ba3039 216-230 325 1.20 26 0.2 1.18 20 0.4 1.25 +20 to +70 t0 n (3) bb3028 bb1028 200-400 (5) 250 25 0.3 1.20 20 0.4 1.25 -20 to +70 t57 n bb3001 (2) bb1001 (2) 225-400 60 0.25 20 0.8 1.25 16 0.8 1.40 -40 to +70 1 sma bb3006 (2) bb1006 (2) 225-400 100 0.25 20 0.8 1.25 17 0.8 1.40 -40 to +70 1 n bb3007 (1,2) 225-400 200 1.00 17 0.7 1.35 14 0.8 1.50 -40 to +60 2 n bb3011 (2) 225-400 300 1.00 14 1 1.50 14 1 1.50 -40 to +80 t56 n (3) bb3019 bb1019 350-400 200 (4) 20 0.3 1.25 18 0.6 1.30 -10 to +55 t2 n (3) bb3080 bb1080 378-512 200 (4) 20 0.3 1.25 18 0.6 1.30 -10 to +55 t2 n (3) bb3025 bb1025 405-450 200 (4) 20 0.3 1.25 18 0.6 1.30 -10 to +55 t2 n (3) bb3038 bb1038 405-470 16 0.75 1.37 16 0.75 1.37 t50 sma bb3023 bb1023 415-430 100 18 0.6 1.30 18 0.6 1.30 -10 to +55 t2 n (3) bb3031 bb1031 415-454 19 0.7 1.30 19 0.7 1.30 -30 to +60 t50 sma bb3026 bb1026 450-500 200 (4) 20 0.3 1.25 18 0.6 1.30 -10 to +55 t2 n (3) bc3019 610-960 50 15 1.1 1.55 15 1.1 1.55 -40 to +95 td sma/int bc3041 bc1041 700-860 200 (4) 20 0.3 1.25 18 0.6 1.30 -10 to +55 t2 n (3) bc3019 760-960 50 19 0.5 1.30 16 0.5 1.45 -40 to +95 td sma bc3006 bc1006 800-960 50 20 0.4 1.25 18 0.5 1.30 -10 to +55 t3 sma bd3003 bd1003 960-1215 50 19 0.4 1.30 17 0.5 1.35 -40 to +85 t3 sma bd3040 960-1215 100 10.00 20 0.45 1.25 20 0.45 1.25 -10 to +65 t2 n (3) standard coaxial circulators & isolators 3-port circulators & isolators (1) high power device. (2) speci?ations are absolute maximum ratings at high power (listed avg. power). (3) with sma, n connectors or tab integrations depending on max. power level request. (4) 200 w-cw on 3: 1 continuous load vswr. permanent short circuit duration: 3 sec. max. 100 w-cw on permanent short circuit handling, cooling by conduction via a heat sink (r th = 0.4 c/w max.). (5) 10 % bandwidth. for more than 50 w-cw input power, cooling is necessary by conduction via heat sink (r th = 0.4 c/w max.) 4-port circulators & isolators ba4140 138 - 155 250 5 45 0.8 1.25 45 0.8 1.25 0 to +70 p0 n ba4113 155 - 174 250 5 45 0.8 1.25 45 0.8 1.25 0 to +70 p0 n ba4217 200 - 207 100 0 50 1.0 1.30 45 1.0 1.30 -10 to +55 p0 n bd4013 960 - 1215 100 5 38 1.0 1.30 35 1.2 1.35 -30 to +70 p2 n 15-23 vol. 1 sales offices: visit our web site at http://www.temex.net
coaxial devices vhf / uhf coaxial circulators & isolators 15-24 vol. 1 sales offices: visit our web site at http://www.temex.net sales offices vhf / uhf 3-port devices - packages 4 holes m4 depth 6 30 all dimensions supporting an asterisk (*) are measured ?nder ?nges . to series t2 series note: on request: reverse direction dimensions in mm tolerances 0.5 33 1.299 13.4 0.528 37 1.457 75 2.953 max. 28 1.102 2.5 0.098 26 1.024 a mounting face n. female n. female bb1028-xx n
coaxial devices vhf / uhf coaxial circulators & isolators 15-25 vol. 1 3 holes m2 ; depth 5 3 2 1 23.7 all dimensions supporting an asterisk (*) are measured ?nder ?nges . sales offices: visit our web site at http://www.temex.net
coaxial devices vhf / uhf coaxial circulators & isolators 15-26 vol. 1 sales offices: visit our web site at http://www.temex.net vhf / uhf 4-port devices - packages 69.5 54.1 10 max 19.75 30 load (5w) connector type"n" female 16 32 9.75 139 119.5 34.75 69.5 connector 6.5 min 3 4xm4 po series all dimensions supporting an asterisk (*) are measured ?nder ?nges . features kmr/sma female connector s (except where noted) kmr/sma male connector s available upon request tabs for microstrip or stripline applications available upon request ( it50 - it1 7 - it27 ) note: on request: reverse direction dimensions in mm tolerances 0.5 on request ??con?uration
coaxial devices vhf / uhf coaxial circulators & isolators 15-27 vol. 1 load (3w) 7 10 52 max 85.6 3.5 96 26 4 88 12 4 m3 tar 4 p2 series 25.8 4 mini 1.8 1.7 6 mini 70 5 60 17.5 63.1 load 3w 4 32.91 6.9 12 2* 4.3 9.3 28.1 41 12*m3 8 max p4 series sales offices: visit our web site at http://www.temex.net
coaxial devices standard coaxial devices 1 to 18 ghz 15-28 vol. 1 sales offices: visit our web site at http://www.temex.net coaxial technology waveguide technology 100 10 1 1 10 100 0.1 frequency ghz standards average power kw standard coaxial devices 1 to 18 ghz
coaxial devices standard coaxial devices 1 to 18 ghz 15-29 vol. 1 temex offers the worldwide market a broad range of coaxial circulators and isolators, covering the frequency range 1 ghz to 18 ghz. this catalog describes standard three-port circulators and isolators. 4-port are available upon request, based on standard 3-port designs. please consult your local sales offices for further information. these devices are used for popular bandwidth, with an average power of 10, 20, 30, 50 w depending on the frequency. seven standards ??packages. the standard unit has kmr/sma female connectors and when used as an isolator, an internal 60 w peak/1 w avg termination on port 3. t1 and t2 series are dedicated to high average power applications. standard cases versus frequency t series h series p series 1234510 t 3 t 1 t 6 t 6 t 9 t 11 18 ghz t 2 general information general description sales offices: visit our web site at http://www.temex.net
coaxial devices standard coaxial devices 1 to 18 ghz 15-30 vol. 1 sales offices: visit our web site at http://www.temex.net bd3037 (1,2) - 1.452 - 1.492 22 0.2 1.20 20 0.3 1.25 250 2.5 0 to +55 450 bd3063 (1, 2) - 1.452 - 1.492 20 0.2 1.22 18 0.3 1.30 350 4.0 0 to +55 50 bd3064 (1, 2) - 1.452 - 1.492 22 0.2 1.20 20 0.3 1.25 100 1.0 0 to +55 380 bd3017 bd1017 1.2 - 1.4 19 0.4 1.30 18 0.5 1.30 50 1.0 -10 to +55 110 bd3018 bd1018 1.4 - 1.7 19 0.4 1.30 18 0.5 1.30 50 1.0 -10 to +55 110 be3019 be1019 2.2 - 2.4 20 0.4 1.25 18 0.5 1.30 10 0.5 -10 to +55 60 be3026 be1026 2.7 - 3.1 20 0.4 1.25 18 0.5 1.30 10 0.1 -10 to +55 60 be3027 be1027 2.8 - 3.1 23 0 3 1 20 20 0.4 1.25 20 0.5 -10 to +70 55 bf3005 bf1005 3.1 - 3.5 23 0.3 1.20 20 0.4 1.25 20 0.5 -10 to +70 55 bf3007 bf1007 3.7 - 4.2 23 0.3 1.20 20 0.4 1.25 20 0.5 -10 to +70 55 bh3005 bh1005 5.9 - 6.4 20 03 1.25 20 0.4 1.25 30 0.3 -25 to +70 25 bh3006 bh1006 6.4 - 7.1 20 0.3 1.25 20 0.4 1.25 30 0.3 -25 to +70 25 bh3007 bh1007 7.1 - 7.8 20 0.3 1.25 20 0.4 1.25 30 0.3 -25 to +70 25 bl3003 bl1003 7.8 - 8.7 20 0.3 1.25 20 0.4 1.25 30 0.3 -25 to +70 25 bl3004 bl1004 8.5 - 9.6 20 0.4 1.25 20 0.5 1.25 30 0.3 -25 to +70 25 bj3011 bj1011 9.6 - 10.6 20 0.4 1.25 20 0.5 1.25 30 0.3 -25 to +70 25 bj3012 bj1012 10.6 - 11.7 20 0.4 1.25 20 0.5 1.25 30 0.3 -25 to +70 25 bj3014 bj1014 12.5 - 13.5 20 0.4 1.25 20 0.5 1.25 30 0.3 -25 to +70 25 bj3009 bj1009 13.5 - 14.5 20 0.4 1.25 20 0.5 1.25 30 0.3 -25 to +70 25 other frequencies available on request ; please consult your local sales office. electrical speci?ations isolation min. db inser. loss max db vswr max speci?ations at 25 c isolation min. db inser. loss max db vswr max spec. in temperature range type frequency range (ghz) avg. power max w peak power max kw circulator isolator circulator weight g. approx. temperature range c notes: (1) with tab integrations ( itn1/itn2 ) or n types connectors (2) devices need to be mounted on an heat suite with thermal resistance of 0.4 c/w max outline drawing t1 : 50.8 x 50.3 x 32 mm approx. outline drawing t2 : 50 x 50 x 26 mm approx. outline drawing t3 : 31.6 x 33.2 x 19 mm approx. outline drawing t6 : 25.4 x 25.8 x 13.7 mm approx. outline drawing t? : 25.4 x 25.8 x 13.7 mm approx. outline drawing t9 : 22 x 25 x 14 mm approx. outline drawing t1 1 : 12.7 x 17.2 x 12.8 mm approx.
coaxial devices standard coaxial devices 1 to 18 ghz 15-31 vol. 1 packages features kmr/sma female connector s (except where noted). kmr/sma male connector s available upon request. tabs for microstrip or stripline applications available upon request ( it50 - it1 7 - it27 ). case l w h a b c d e f g holes t1 50.8 50.3 32 44.8 34.1 0 37 25.4 3 (2 plces up) 4 3 x m3 25.4 (1 plce down) t2 50 50 26 39.6 - 20 35.5 25 5.2 through 2 x 3.5 all dimensions in mm 37 34.1 50.3 3 n femelle 50.8 44.8 2 * 3 m 3 4 * m 3 12 32 34.3 39.6 20 3 connectors n female 2 holes 3.5 thru 26 35.5 3 1 2 50 5.2 50 t1 series t2 series t1 series t2 series sales offices: visit our web site at http://www.temex.net
coaxial devices standard coaxial devices 1 to 18 ghz 15-32 vol. 1 sales offices: visit our web site at http://www.temex.net packages features kmr/sma female connector s (except where noted). kmr/sma male connector s available upon request. tabs for microstrip or stripline applications available upon request ( it50 - it1 7 - it27 ). all dimensions supporting an asterisk(*) are measured ?nder ?nges . 3 holes m2, depth 5 31.6 27 t3 series t6 series t? series t9 series t11
coaxial devices connectors & tabs 15-33 vol. 1 connectors & tabs 8.6 12.7 4 holes ? 2.8 30 24 2.5 socket ? 4.1 tellon ? 0.6 5.7 ? 1.35 4.1 ? 12.7 * 2 4.3 8.6 2 holes ? 3 * 9.1 ? 0.4 ? 3.2 6.35 teflon 8 max 1w - 10 w 6.5 15 w 8.6 12.7 4 holes ? 2.5 27 21 * 3.5 0.1 sma female core 3.64 ? 4.1 teflon ? 6 female male 7.6 9.5 female male 9.6 19.9 connectors tabs and terminations kmr/sma connectors n connectors it50 it17 2 .079 8 .315 16 .630 25.4 1.000 2 .079 8 .315 25 .984 158 .062 itn1 itn2 it27 terminations depending on power handling, connectorized devices are available with integrations at any place, instead of the n connectors: on requirements, we can offer devices with, n, sma or tab style connections. sales offices: visit our web site at http://www.temex.net
waveguide devices selection guide 15-34 vol. 1 sales offices: visit our web site at http://www.temex.net waveguide devices selection guide page y -junction 352 mh z t o 1 8 gh z 15-35 4-por t differential pha se shift cir cula t or s 15-42 millimeter w a veguide devices 1 8 t o 40 gh z 15-48
waveguide devices y-junction waveguide devices 352 mhz to 18 ghz 15-35 vol. 1 sales offices: visit our web site at http://www.temex.net y-junction waveguide devices 352 mhz to 18 ghz coaxial technology waveguide technology 100 10 1 1 10 100 0.1 frequency ghz y-junction devices average power kw temex?success in fer rite material and ferrite component manufacturing is due largely to our approach towards computer-aided engineering design and advanced manufacturing technology (numerical controlled fabrication). low-insertion loss and high isolation are not the only criteria to consider when designing junction circulators. broadband, high power handling capability, low 3rd order intermodulation products and low rf leakage are also important. temex?r & d teams developed new materials and technologies, thereby increasing the average power handling for most of the junction circulators. over the past years, cw-power handling has tripled. three-port junctions are available in t- or y- con?urations in the most popular waveguide standards. circulators can be cascaded to form four- or ?e-port devices. water cooling is required on several of the high-power devices. when size is critical, temex supplies compact and miniaturized isolators. they work on narrow-band and low-power applications of up to 10 w mean power. y-junction circulators are either cast or machined. options such as direction of circulation, frequency range, temperature range, and magnetic and electrical shielding are available upon request. general description
waveguide devices y-junction waveguide devices 352 mhz to 18 ghz 15-36 vol. 1 sales offices: visit our web site at http://www.temex.net fb3002 0.352 10 1300 k 1300 - - - 20 0.15 1.20 +25 udr 3 2000 x 1600 x 800 1300 4-8 fb3001 0.4333 0.5 200 k 6000 - - - 25 0.2 1.10 +30 udr 5 1500 x 1500 x 700 1500 fc3003 0.915 2 50 k 50 18 0.2 1.30 15 0.2 1.45 25 5 udr 9 500 x 389 x 213 41 4-5 fe3005 2.450 25 3 k 3 - - - 20 0.15 1.20 +5 to +45 ug 554/u 180 x 190 x 105 6 1-4-9 fe3002 2.450 25 6 k 6 - - - 20 0.15 1.20 +10 to +40 ug554/u 180 x 190 x 127 6 10-1-4-9 fe1021 2.450 25 6k 6 - - - 20 0.15 1.20 +10 to +40 ug554/u 180 x 230 x 115 6.3 10-1-4-5 fe1022 2.450 25 3k 3 - - - 20 0.15 1.20 +10 to +40 ug554/u 180 x 230 x 115 6.3 4-5 fe3036 2.450 25 3k 3 - - - 20 0.25 1.20 +10 to +40 cpr284f 148 x 182 x 106 fe3007 2.850 - 3.300 full 1.5 k 100 23 0.3 1.15 20 0.3 1.20 0 to +55 cmr284 180 x 160 x 99 4.5 1-2-4-5 fe3001 2.998 5 2.5 k 2500 - - - 30 0.15 1.10 +35 to +45 cpr284 f 203 x 155 x 182 8 ff3004 3.4 - 3.8 full 150 10 30 0.2 1.07 26 0.2 1.10 0 to +50 cmr229 127 x 121 x 51 0.5 ff3003 3.7 - 4.2 full 150 10 30 0.2 1.07 26 0.2 1.10 0 to +50 cmr229 127 x 121 x 51 0.5 fg3004 4.4 - 5 full 25 - 28 0.2 1.10 28 0.2 1.10 0 to +50 uer48 118 x 115 x 47 0.5 fg3005 4.4 - 5 full 1.5 k - 25 0.2 1.15 20 0.3 1.15 -10 to +55 uer48 120 x 120 x 74 1.9 fg3007 5.4 - 5.9 full 1.5 k 70 23 0.3 1.15 23 0.3 1.15 0 to +60 ug407 120 x 120 x 95 1.9 fh3013 5.925 - 6.425 full 300 - 32 0.1 1.05 28 0.1 1.08 +5 to +50 cmr137f 83 x 83 x 40 0.23 fh3008 5.925 - 6.425 full 1 k - 25 0.15 1.15 20 0.2 1.15 -10 to +50 cmr137f 83 x 83 x 75 0.4 3-4 fh3006 5.850 - 6.425 full 3.5 k - 25 0.15 1.15 25 0.15 1.15 -10 to +50 cpr137f 83 x 125 x 86 3-4 fh3007 5.850 - 6.425 full 6 k - 25 0.15 1.15 25 0.15 1.15 -10 to +50 cpr137f 83 x 125 x 86 1.4 7 fh3001 5.925 - 7.110 full 30 - 28 0.1 1.08 28 0.1 1.10 0 to +50 cmr137f 83 x 82 x 40 0.23 fh3009 6.425 - 7.110 full 25 10 32 0.1 1.05 28 0.1 1.08 0 to +55 cmr137f 83 x 82 x 40 0.23 fh3010 6.425 - 7.110 full 25 10 32 0.1 1.05 28 0.1 1.08 0 to +55 cmr137f 120 x 90 x 39 0.23 fh3011 7.110 - 7.700 full 25 - 30 0.15 1.06 28 0.15 1.08 0 to +55 cmr137f 83 x 80 x 50 0.7 fh3022 7.1 - 8.5 full 20 - - - - 20 0.2 1.22 -5 to+70 fh3003 7.5 - 8.5 full 25 5 25 0.2 1.15 20 0.3 1.20 0 to +60 ubr84 68 x 67 x 51 0.3 4 fl3002 7.9 - 8.4 full 200 - 25 0.2 1.15 20 0.3 1.20 0 to +60 ubr84 68 x 67 x 51 0.3 3-4 fl3005 7.9 - 8.4 full 4.3 k - 25 0.15 1.15 25 0.15 1.15 -10 to +60 ubr84 68 x 67 x 77 0.55 isolation min. db ins. loss max. db vswr max. speci?ations at 25 c isolation min. db ins. loss max. db vswr max. spec. in temperature range frequency range (ghz) band- width (mhz) peak power max. kw avg. power max. w temperature range ? dimensions weight flange mm kg. approx. approx. notes type wr2300 waveguide (r3) wr340 waveguide (r26) wr284 waveguide (r32) wr1 80 0 waveguide (r5) wr975 waveguide (r9) notes: 1 water cooled 6 max. avg. power into matched load only 2 pressurization sf 6 - 10 psig 7 low third order intermodulation products 3 forced air cooled 8 water cooled at 30 c and pressurization sf 6 - 1.5 psig 4 into external load 2: 1 continuous 9 permanent short circuit handling 5 short circuit handling 10 ms duration 10 isolator with integrated water load outline drawings see page 1 5-38 and following. electrical characteristics wr1 12 waveguide (r84) wr137 waveguide (r70) wr1 87 waveguide (r48) wr229 waveguide (r40)
waveguide devices y-junction waveguide devices 352 mhz to 18 ghz fl3007 8.2 -10.5 full 25 5 21 0.3 1.20 20 0.4 1.20 -20 to +85 ug 39/u 60 x 52 x 41 0.2 2 fl3004 8.5 - 9.6 full 300 110 22 0.4 1.20 18 0.5 1.30 -40 to +85 ug 39/u 60 x 52 x 41 0.2 fl3001 9.4 - 9.7 full 20 5 26 0.3 1.10 26 0.3 1.10 -30 to +80 ug 39/u 57 x 57 x 41 0.3 fj3019 10.5 - 12.2 full 25 5 25 0.3 1.15 20 0.5 1.20 -10 to +50 ug 39/u 60 x 52 x 41 0.2 fj3020 10.7 - 11.7 full 25 5 30 0.2 1.07 26 0.2 1.12 -20 to +60 ubr120 44.5 x 44.5 x 38 0.19 fj3021 11.7 - 12.5 full 25 5 30 0.2 1.07 26 0.2 1.12 -20 to +60 ubr120 44.5 x 44.5 x 38 0.16 fj3022 12.5 - 13.5 full 25 5 30 0.2 1.07 26 0.2 1.12 -20 to +60 ubr120 44.5 x 44.5 x 38 0.14 fj3018 14 - 14.5 full 25 5 30 0.2 1.07 26 0.2 1.12 -20 to +60 ubr120 44.5 x 44.5 x 38 0.15 3-6 fj3017 14 - 14.5 full 450 0.5 25 0.1 1.15 25 0.1 1.15 -10 to +60 ubr120 44.5 x 44.5 x 51.2 0.18 3-6 fj3011 14 - 14.5 full 200 0.2 28 0.25 1.05 25 0.25 1.15 -10 to +50 udr120 61 x 55 x 58 0.7 3-6 fj3010 14 - 14.5 full 2 k 2 28 0.25 1.05 25 0.25 1.15 -10 to +50 udr120 61 x 63 x 90 0.7 fj3023 12.5 - 14 full 15 5 22 0.3 1.20 20 0.3 1.20 -40 to +70 ug419/u 38 x 40 x 35 0.14 fj3004 15.5 - 17 full 15 5 22 0.3 1.20 20 0.3 1.20 0 to +60 ug419/u 38 x 40 x 35 0.14 8 fj3025 16 - 17 full 55 55 22 0.4 1.20 18 0.5 1.30 -40 to +90 ug419/u 38 x 40 x 35 0.14 fj3001 17.7 -19.7 full - - 25 0.3 1.15 23 0.3 1.15 0 to + 50 special 38 x 40 x 32 0.1 notes: 1 water cooled 2 pressurization air - 15 psig 3 forced air cooled 4 into external load 2 : 1 continuous 5 short circuit handling 10 ms duration 6 max. avg. power into matched load only 7 low third order intermodulation products 8 pressurization air 30 psig outline drawings see page 1 5-38 and following. isolation min. db ins. loss max. db vswr max. isolation min. db ins. loss max. db vswr max. frequency range (ghz) band- width (mhz) peak power max. kw avg. power max. w temperature range ? flange notes type weight kg. approx. dimensions mm approx. speci?ation at 25 c spec. in temperature range wr90 waveguide (r100) wr75 waveguide (r120) wr62 waveguide (r140) wr51 waveguide (r180) 15-37 vol. 1 sales offices: visit our web site at http://www.temex.net
waveguide devices y-junction waveguide devices 352 mhz to 18 ghz 15-38 vol. 1 sales offices: visit our web site at http://www.temex.net outline drawings r32 wr284 waveguide r40 wr229 waveguide 6.5 6 155 80 107.7 203.2 170 101.58 8.5 6 132 182 32 127 79 3 2 51 121 120 74/95 120 2 3 73.7 1 118.3 114.83 47 4.5 78.5 r48 wr187 waveguide fe3001 fg3004 fg3005 - fg3007 ff3003 - ff3004 r5 wr1800 waveguide 383 676 465 fb3001
waveguide devices y-junction waveguide devices 352 mhz to 18 ghz r70 wr137 waveguide 82.55 fan 171 max 67.24 fan 93 93 m5 delph 8 mini 85.8 m5 depth 8 mini 125 61.24 82.55 75 82 82.6 3 2 51 1 40 15.8 58 34.85 51 82.6 65 58 32 82 80 6.5 fh3006 fh3013 fh3008 fh3007 r70 wr137 waveguide 39 89.5 3 120 1 2 60.5 40 82 3 2 1 82.6 51 fh3010 fh3001 - fh3009 82.6 32 51 50 80 1 fh3011 15-39 vol. 1 sales offices: visit our web site at http://www.temex.net
waveguide devices y-junction waveguide devices 352 mhz to 18 ghz 15-40 vol. 1 sales offices: visit our web site at http://www.temex.net r120 wr75 waveguide r180 44.5 24.6 3 2 1 38.1 44.5 fj3018 - fj3020 - fj3021 - fj3022 r84 wr112 waveguide 67 32 42 50 67 77 max m4 depth 5mm 3 2 1 67 42 67 68 max 41 57 57 3 2 36.5 3 1 2 53 3.5 3.5 3.5 3.5 32.5 31 3.5 30.87 41 51.8 r100 wr90 waveguide fh3003 - fi3002 fi3004 - fi3007 - fj3019 fi3001 fi3005
waveguide devices y-junction waveguide devices 352 mhz to 18 ghz r120 wr75 waveguide 44.5 m4 delph 5 min 52.1 44.5 24.6 61 3 2 1 30.5 90 63 40 35 32 23.5 38 3 2 30.5 1 61 58 55 r120 wr75 waveguide r140 wr62 waveguide fj3017 fj3011 fj3004 - fj3023 fj3010 23.5 3 2 38 40 32 fj3001 r180 wr51 waveguide r140 wr62 waveguide 23.7 38 3 2 35 40 fj3025 15-41 vol. 1 sales offices: visit our web site at http://www.temex.net
waveguide devices 4-port waveguide differential phase shift circulators (duplexers) 15-42 vol. 1 sales offices: visit our web site at http://www.temex.net 4-port waveguide differential phase shift circulators (duplexers) coaxial technology waveguide technology 100 10 1 1 10 100 0.1 frequency ghz differential phase shift duplexers average power kw designed for use in both high-peak and high-mean power applications, temex differential phase shift circulators offer high isolation while maintaining low-insertion loss. these ruggedly constructed circulators can operate under the most severe environmental conditions, according to mil-spec. the addition of speci? heat sinks, or liquid cooling jackets increases mean power handling; for example, of up to 200 kw-cw at 1.250 ghz. casting techniques can be used for pressurized waveguide in order to reduce leakage and weight, especially for airborne radar. in-house fer rite materials facilities, computer-aided design, and experienced research and development teams, allow temex to offer customers speci? designs with optimal features. with the addition of a suitable waveguide load and a dummy load on the appropriate port, a 4-port differential phase shift circulator may be operated as a high-power isolator. the re?cted power that will be absorbed in the dummy load, or the output mismatch - (v.s.w.r.) - should be speci?d when ordering. options such as direction of circulation, mechanical output ports e-bend or h-bend are available upon request. general description
waveguide devices 4-port waveguide differential phase shift circulators (duplexers) 1-5 fc6001 1.000 - 350 k 350 - - - 20 0.15 1.10 25 3 udr 9 3044 - 1-4 fd6001 1.250-1.350 full 6 k 6500 2o 0.5 1.15 2o 0.5 1.15 -10 to +50 cpr 650 2075 80 1-7 fd6002 1.250-1.350 full 200 k 2000 2o 0.2 1.15 2o 0.2 1.15 +10 to +40 cpr 650 2136 130 1 fe6002 2.450 25 50 k 50 23 0.2 1.15 20 0.25 1.2o +10 to +30 ug 554a/u 1125 43 2-4 fe6004 2.700-2.900 full 3 k 1500 25 0.4 1.20 25 0.4 1.20 0 to +65 special 600 25 1 fe6005 2.900-3.100 full 10 k 660 25 0.4 1.20 25 0.4 1.20 0 to +50 special 965 19 1-5-7 fe6001 2.900-3.100 full 6 k 6000 2o 0.3 1.15 20 0.3 1.15 0 to +50 cpr 284f 635 40 1-6 fe6003 2.995-3.005 full 7 k 15000 20 0.2 1.05 20 0.2 1.05 +15 to +30 special 902 80 2 fg4201 4.4-5 full 2 k 2 23 0.2 1.12 23 0.2 1.12 -10 to +40 uer 48 588 8 2 fh6002 5.925-6.425 full 1.5 k - 22 0.15 1.07 20 0.2 1.15 -10 to +65 cpr 137 418 4.8 2 fh6000 5.925-6.425 full 3 k - 22 0.15 1.07 2o 0.2 1.15 -10 to +65 cpr 137 418 4.8 fi6006 7.9-8.4 full 1.8 k - 30 0.2 1.10 30 0.2 1.10 -10 to +70 ug 138/u 324 1.6 2-4 fl6007 8.5-9.6 full 300 250 25 0.5 1.15 23 0.5 1.15 0 to +60 ug 138/u 324 1.6 2-4 fl6003 8.8-9.4 full 250 250 25 0.5 1.15 25 0.5 1.15 0 to +60 ug 138/u 254 0.7 2-4 fi6001 8.5-9.6 full 300 250 20 0.5 1.20 20 0.5 1.20 -40 to +70 ug 135/u 176 0.52 3 fi6008 9-9.6 full 540 180 22 0.4 1.20 20 0.5 1.20 -40 to +70 ug 135/u 152 0.52 2-4 fj6013 9.6-10.4 full 1500 50 - - - 20 0.3 1.15 -40 to +70 ug 135/u 200 0.5 fj6008 9.9-10.5 full 500 - 22 0.3 1.20 20 0.5 1.20 -30 to +60 ug 135/u 207 1 1 fj6004 10-10.25 full 2.5 k - 25 0.25 1.10 20 0.35 1.15 0 to +60 ug 39/u 246 2.1 1 fj6007 11.7-12.5 full 1 k 2 25 0.25 1.15 20 0.3 1.20 0 to +60 ubr 120 257 2.2 2 fj6001 14-14.5 full 2.5 k 2.5 25 0.25 1.15 22 0.3 1.20 -10 to +55 ug 419/u 223 3.2 fj6009 15.7-17 full 150 60 20 0.4 1.15 20 0.4 1.15 -10 to +70 ug 419/u 171 0.55 electrical characteristics isolation. min. db inse. loss max. db vswr max. speci?ations at 25 c isolation. min. db inse. loss max. db vswr max. spec. in temperature range frequency range (ghz) band- width (mhz) peak power max. kw avg. power max. w temperature range ? flange notes type weight kg. approx. length mm approx. wr975 waveguide (r9) wr650 waveguide (r14) wr340 waveguide (r26) wr284 waveguide (r32) wr1 87 waveguide (r48) wr137 waveguide (r70) wr1 12 waveguide (r84) wr90 waveguide (r100) wr75 waveguide (r120) wr62 waveguide (r140) notes: 1 water cooled 5 can operate with permanent short circuit 2 air cooled 6 pressurized sf 6 (45 psig) 3 air cooled pressurized 30 psig (2 kg) 7 pressurized sf 6 (15 psig) 4 pressurized 15 psig (1.1 kg) 15-43 vol. 1 sales offices: visit our web site at http://www.temex.net
waveguide devices 4-port waveguide differential phase shift circulators (duplexers) 15-44 vol. 1 sales offices: visit our web site at http://www.temex.net r32 wr284 waveguide outline drawings r14 wr650 waveguide r26 wr340 waveguide load antenna 2075/2136 transmitter receiver inlet outlet 1125 1 3 4 2 4 2 965 2 1 1 197 83 869.2 2 output 72 outlet inlet 27 600 load antenna transmitter receiver 63.5 88.4 635 52 73 max 67.07 136.5 128 200 max. fd6001 - fd6002 fe6004 fe6003 fe6001 fe6005 fe6002
waveguide devices 4-port waveguide differential phase shift circulators (duplexers) r70 wr137 waveguide r48 wr187 waveguide 40 139 max. 85 max. 63.5 140 max. 315 max. 1 160 max. 588 25.7 2 417.7 418 63 fg4201 fh6002 fh6000 r84 wr112 waveguide 2 4 324 1 3 254 antenna receiver transmitter fi6003 fi6006 - fi6007 15-45 vol. 1 sales offices: visit our web site at http://www.temex.net
waveguide devices 4-port waveguide differential phase shift circulators (duplexers) 15-46 vol. 1 sales offices: visit our web site at http://www.temex.net r100 wr90 waveguide r100 wr90 waveguide 66.4 207.5 input 1 2 (input) output 2 4 152.5 3 1 53.8 antenna load 246 51 transmitter receiver 176 1 2 fj6008 fi6008 fj6004 fi6001
waveguide devices 4-port waveguide differential phase shift circulators (duplexers) r120 wr75 waveguide load 257 45 antenna receiver 47 transmitter 50 48 171 fj6007 r140 wr62 waveguide 4 2 223 1 3 fj6001 fj6009 15-47 vol. 1 sales offices: visit our web site at http://www.temex.net
waveguide devices millimeter waveguide devices 18 to 40 ghz 15-48 vol. 1 sales offices: visit our web site at http://www.temex.net millimeter waveguide devices 18 to 40 ghz coaxial technology waveguide technology 100 10 1 1 10 100 mm-wave 0.1 frequency ghz average power kw temex is actively involved in the in-house development of fer rite materials used in millimeter wave circulators, isolators and duplexers. our proprietary cad software is the result of years of microwave device design experience. this has enabled us to optimize technological features in three product lines: y-junction circulators (h-plane con?uration), miniature isolators (these are y-junctions with an internal termination), 4-port differential phase shift circulators. these devices cover 18 to 94 ghz in seven standard waveguide sizes with an average power up to 1500 w at 30 ghz. options such as direction of circulation, y- or t- shaped junctions, compact size, speci? ?nges and cascaded devices are available upon request. general information
waveguide devices millimeter waveguide devices 18 to 40 ghz 2 fj3008 18-21 full 15 2 23 0.4 1.15 20 0.5 1.20 -40 to +70 ug 597/u 32 x 32 x 26 80 2 fk3001 27-32 full 2 2 20 0.4 1.25 20 0.5 1.25 -10 to +60 ug599/u 30 x 31 x 24 80 2 fk3007 33-37 full 2 2 20 0.4 1.25 20 0.5 1.25 -10 to +60 ug599/u 30 x 31 x 24 80 3-4 fk6001 34.5-35.5 full 50 50 20 0.5 1.20 20 0.5 1.20 -10 to +85 ug599/u 127 x 44 x 35 320 2 fk3002 35-40 full 2 2 20 0.4 1.25 20 0.5 1.25 -10 to +60 ug599/u 30 x 31 x 24 80 1 fk1016 37-39.5 full 1 - 20 0.3 1.20 17 0.5 1.25 -30 to +80 ug599/u 13 x 32 x 19.6 - 1 fk3016 37-39.5 full 1 - 20 0.3 1.20 17 0.5 1.25 -30 to +80 ug599/u 13 x 32 x 19.6 - notes: (1) miniature isolator (2) y-junction circulator (3) 4-port differential phase shift circulator (duplexer) (4) air cooled pressurized 2 kg isolation min. db inse. loss max. db vswr max. speci?ations at 25 c isolation min. db inse. loss max. db vswr max. spec. in temperature range frequency range (ghz) band- width (mhz) peak power max. kw avg. power max. w temperature range ? flange notes type weight g. approx. dimensions mm approx. wr28 waveguide (r320) electrical characteristics wr42 waveguide (r220) n 32 0.5 13 0.05 19.6 0.2 0.2 a a 3.56 0.02 6.35 12.7 b 4 trs. ?4-40 unc 2b d?bts ?0.05 a-b 6.73 13.46 9.65 0.1 7.11 0.02 19.05 12 3 25.4 0.1 a-b 19.05 outline drawings 15-49 vol. 1 sales offices: visit our web site at http://www.temex.net
design aid selection guide 15-50 vol. 1 sales offices: visit our web site at http://www.temex.net design aid selection guide page interna tional designa tions for s t and ard rect angular w a veguides 15-51 interna tional designa tions for flanges 15-53 effect of vswr on transmit ted po wer 15-55
design aid international designations for standard rectangular waveguides 15-51 vol. 1 1 0.320 - 0.490 593.8 301.7 584.2 292.1 3.18 1-001 1-002 1-161 2 0.340 - 0.535 543.0 276.3 533.4 266.7 3.18 1-003 1-004 1-162 3 0.410 - 0.620 436.6 235.0 457.2 228.6 3.18 1-005 1-006 1-163 1-a01 4 0.490 - 0.750 387.6 196.9 381.0 190.5 3.18 1-007 1-008 1-164 1-a02 5 0.640 - 0.975 298.5 152.4 292.1 146.05 3.18 1-009 1-010 1-165 1-a03 6 0.755 - 1.150 254.0 130.2 247.65 123.82 3.18 1-011 1-012 1-166 1-ao4 7 0.960 - 1.46 195.6 97.8 195.58 97.79 3.18 1-013 1-014 1-167 1-a05 8 1.13 - 1.73 169.2 86.6 165.10 82.55 0.33 2.03 1-015 1-017 1-018 1-019 1-168 1-a06 3a06 9 1.45 - 2.20 133.6 68.8 129.54 64.77 0.26 2.03 1-021 1-023 1-025 1-026 1-169 10 1.72 - 2.61 113.3 58.7 109.22 54.61 0.22 2.03 1-027 1-031 1-029 1-030 1-170 1-a08 3a08 11 2.12 - 3.20 88.9 44.45 0.17 2.03 12 2.17 - 3.30 90.42 47.24 86.36 43.18 0.17 2.3 1-033 1-037 1-035 1-036 1-171 1-a09 3a09 13 2.60 - 3.95 76.20 38.10 72.14 34.04 0.14 2.03 1-039 1-043 1-041 1-042 1-172 1-a10 3a10 14 3.22 - 4.90 61.42 32.33 58.17 29.08 0.12 1.63 1-045 1-049 1-047 1-048 1-173 15 3.95 - 6.00 50.80 25.40 47.55 22.15 0.095 1.63 1-0.51 1-055 1-053 1-054 1-174 1-a12 3a12 16 4.65 - 7.05 43.64 23.44 40.39 20.19 0.081 1.63 1-057 1-061 1-059 1-060 1-175 17 5.4 - 8.2 38.10 19.05 34.85 15.80 0.070 1.63 1-063 1-067 1-065 1-066 1-176 1-a14 3a14 18 6.55 - 10.0 31.75 15.88 28.50 12.62 0.06 1.63 1-069 1-073 1-071 1-072 1-177 1-a15 3a15 19 8.2 - 12.5 25.40 12.70 22.86 10.16 0.05 1.27 1-075 1-079 1-077 1-078 1-078 1-a16 3a16 20 9.8 - 15.0 21.59 12.06 19.05 9.52 0.04 1.27 1-081 1-085 1-083 1-084 1-179 21 11.9 - 18.0 17.83 9.93 15.80 7.90 0.03 1.02 1-093 1-087 1-089 1-090 1-091 1-180 1-a18 6-a18 3a18 22 14.5 - 22.0 14.99 8.51 12.95 6.48 0.026 1.02 1-094 1-096 1-097 1-098 1-181 23 18.0 - 26.5 12.70 6.35 10.67 4.32 0.022 1.02 1-106 1-100 1-102 1-103 1-104 1-182 1-a20 6-a20 3a20 24 22.0 - 33.0 10.67 6.35 8.64 4.32 0.020 1.02 1-113 1-107 1-109 1-110 1-111 1-183 25 26.5 - 40.0 9.14 5.59 7.11 3.56 0.020 1.02 3-006 3-007 3-008 * 3-009 6-a22 26 33.0 - 50.0 7.72 4.88 5.69 2.845 0.020 1.02 3-010 3-012 3-013 * 3-013 6-a23 27 40.0 - 60.0 6.81 4.42 4.78 2.39 0.020 1.02 3-014 3-015 3-016 * 28 50.0 - 75.0 5.79 3.91 3.79 1.88 0.020 1.02 3-017 3-018 3-019 * 6-a25 29 60.0 - 90.0 5.13 3.58 3.10 1.55 0.015 1.02 3-020 3-021 3-022 * 6-a26 30 75.0 - 110.0 4.57 3.30 2.54 1.27 0.010 1.02 3-023 3-024 3-025 * 31 90.0 - 140.0 3.56 2.54 2.032 1.016 0.008 0.76 3-026 3-027 3-028 * 32 110.0 - 170.0 3.175 2.35 1.651 0.826 0.0064 0.76 3-029 3-030 3-031 * 33 140.0 - 220.0 2.819 2.172 1.296 0.648 0.0064 0.76 3-032 3-033 3-034 * 34 170.0 - 260.0 2.616 2.070 1.092 0.546 0.0051 0.76 3-035 3-036 3-037 * 35 220.0 - 325.0 2.388 1.956 0.864 0.432 0.0051 0.76 3-038 3-039 3-040 * international designations for standard rectangular waveguides waveguide size outer inner tolerances wall dimensions dimensions thickness mm mm mm mm designation m - 85 - ( ) ag cu brass aluminum alloy or (cu + ag)* 1100 6061 6063 width height width height (a) (b) (a) (b) frequency range (te 01 mode) ghz norm: nato designation ngw - ( ) al ag brass 110 0 norm: mil - w - 85 (usa) (2) pulse length: 1? - breakdown strength (dry air): 15 kv/cm - p = 15 psia sales offices: visit our web site at http://www.temex.net
design aid international designations for standard rectangular waveguides 15-52 vol. 1 sales offices: visit our web site at http://www.temex.net 1 00 290 2300 3 0.256 0.164 0.099 153 212 5900 8500 2 0 291 2100 4 0.281 0.173 0.109 120 173 4500 6800 3 1 201 1800 5 0.328 0.180 0.122 93.4 132 3200 4900 4 2 202 1500 6 0.393 0.220 0.160 67.6 93.3 2100 3100 5 3 203 1150 8 0.513 0.336 0.240 35 53.8 1150 1700 6 4 204 975 9 0.605 0.440 0.305 27 38.5 760 1200 7 5 205 770 12 0.766 0.635 0.436 17.2 24.1 450 700 8 6 69 103 650 14 0.908 0.88 0.58 118 17.1 300 480 9 7 337 338 510 18 1.157 1.123 0.84 7.5 10.6 180 270 10 8 104 105 430 22 1.373 1.63 1.08 5.2 7.5 115 190 11 9 1.686 12 9a 112 113 340 26 1.737 2.21 1.54 3.4 4.7 72 110 13 10 48 75 284 32 2.078 2.40 1.64 2.18 3.1 45 67 14 11a 340 341 229 40 2.579 3.92 2.78 1.56 2.14 30 46 15 12 49 95 187 48 3.155 5.79 4.00 0.94 1.32 18 24 16 13 343 344 159 58 3.714 6.62 6.00 0.754 0.983 12 19 17 14 50 106 137 70 4.285 8.19 6.47 0.554 0.696 8 12 18 15 51 68 112 84 5.260 11.5 8.91 0.355 0.454 51 7.6 19 16 52 67 90 100 6.560 17.9 12.4 0.206 0.896 32 4.5 20 17 346 347 75 120 7.873 21.2 14.8 0.166 0.229 24 3.4 21 18 107 91 349 62 140 9.490 26.7 19.6 0.119 0.157 16 2.2 22 19 353 **352 351 51 180 11.578 36.5 36.4 0.079 0.106 100 1.4 23 20 66 53 121 42 220 14.080 57.1 42 0.043 0.058 0.53 0.8 24 21 *357 34 260 17.368 53 36.8 0.034 0.047 0.4 0.6 25 22 96 *271 28 320 21.100 72 49.2 0.023 0.32 0.28 0.4 26 23 97 **272 22 400 26.350 101 68 0.014 0.020 0.17 0.26 27 24 *358 19 500 31.410 127 89 0.010 0.014 0.14 0.20 28 25 98 *273 15 620 39.900 188 128 0.0063 0.0090 29 26 99 *274 12 740 48.400 257 172 0.0042 0.060 30 27 *359 10 900 59.050 330 232 0.0028 0.0040 31 28 138 *278 8 1200 73.840 500 325 0.0018 0.0026 32 29 136 *276 7 1400 90.485 715 449 0.0012 0.0017 33 30 135 *275 5 1800 115.75 1010 633 0.00071 0.00107 34 31 137 *277 4 2200 137.52 1260 833 0.00052 0.00075 35 32 139 3 2600 173.29 1660 1140 0.00035 0.00047 norm: jan (usa) norm: eia (usa) e.i.c. official norm official designation r - ( ) designation wr - ( ) te 10 mode theoretical theoretical max copper guide cut-off attenuation peak power ( ? designation rg - ( ) brass ag *cu-ag al **cu norm: uk designation wg - ( )
design aid international designations for ?nges 15-53 vol. 1 ca-r( ) cb-r( ) pa-r( ) pb-r( ) pc-r( ) pd-r( ) pf-r( ) ua-r( ) ub-r( ) ud-r( ) ue-r( ) 1 x x 2300 3 2 x x 2100 4 3 x x 1800 5 4 x x 1500 6 5 x x 1150 8 6 x x 975 9 7 x x 770 12 8 x x 650 14 9 x x 510 18 10 x x 430 22 11 x x 340 26 12 x x x x x x 284 32 13 x x x 229 40 14 x x x x x x 187 48 15 x x x x x x 159 58 16 x x x x x x 137 70 17 x x x x x x 112 84 18 x x x x x x 90 100 19 x x x x 75 120 20 x x x x x 62 140 21 x x 51 180 22 x x x x 42 220 23 x 34 260 24 x x x x 28 320 381 67 b005 25 x 22 400 383 67 b006 26 x 19 500 383 n 67 b007 27 x 15 620 385 67 b008 28 x 12 740 387 67 b009 29 x 10 900 387 m 67 b010 30 x 8 1200 387 m 74 - 001 31 7 1400 387 m 74 - 002 32 5 1800 387 m 74 - 003 33 4 2200 34 3 2600 35 uh-r 36 x 35 37 x 41 international designations for flanges flanges official designations: iec norm flange waveguide a c (1) b c r - ( ) iec-p (2) d e u (3) f waveguide norm: eia wr - ( ) norm: iec r - ( ) norm: eia wr - ( ) brass norm: eia wr - ( ) circular pin flange notes: (1) pressurizable with ?hoke ?nges (2) pressurizable (3) no-pressurizable sales offices: visit our web site at http://www.temex.net
design aid international designations for ?nges 15-54 vol. 1 sales offices: visit our web site at http://www.temex.net 1 2300 2 2100 3 1800 4 1500 5 1150 6 975 7 770 8 417 b 1714 1362 418 b 1720 1343 650 9 1715 1718 1717 1719 510 10 435 a 1716 1344 437 a 1711 1345 430 b 11 553 a 1712 1346 554 a 1713 1747 340 12 53 1479 1724 1348 584 1484 1725 1349 54 a 585 a 284 284 13 1726 1350 1727 1351 229 229 14 149 a 1475 1728 1352 407 1480 1729 1353 148 b 406 a 187 187 cb 15 1730 1354 1731 1355 159 159 16 344 1476 1732 1356 441 1481 1733 1357 343 a 440 a 137 137 bb 17 51 1477 1734 1358 138 1482 1735 1359 52 a 137 a 112 112 b 18 39 1478 1736 1360 135 1483 1737 1371 40 a 136 a 90 90 19 20 419 1665 541 a 1666 21 597 596 a 596 a 22 505 23 24 599 600 a b 25 599 n 1521 26 599 n 27 599 m 1523 28 599 m 1522 19 30 31 32 33 34 35 36 37 flanges norm: jan ug - ( ) / u ?tandard ?hoke flange brass aluminum alloy brass ?lat ~ cmr ~ cpr-f ~ cpr-g ?lat ~ cmr ~ cpr-f ~ cpr-g aluminum alloy norm: eia cmr - ( ) f: flat norm: eia cpr - ( ) f: flat g:groove
design aid effect of v.s.w.r. on transmitted power 15-55 vol. 1 1.00 .0 .000 .00 100.0 .0 1.64 4.3 12.3 .263 .24 94.1 5.9 1 01 .1 46.1 .000 .00 100.0 .0 1.66 4.4 12.1 .276 .25 93.8 6.2 1.02 .2 40.1 .000 .01 100.0 .0 1.68 4.5 11.9 .289 .25 93.6 6.4 1 03 .3 36.6 .001 .01 100.0 .0 1.70 4.5 11.7 .302 .26 93.3 6.7 1 04 .3 34.2 .002 .02 100.0 .0 1.72 4.7 11.5 .315 .26 93.0 7.0 1.05 .4 32.3 .003 .02 99.9 .1 1.74 4.8 11.4 .329 .27 92.7 7.3 1.06 .5 30.7 .004 .03 99.9 .1 1.76 4.9 11.2 .342 .28 92.4 7.6 1.07 .6 29.4 .005 .03 99.9 .1 1.78 5.0 11.0 .356 .28 92.1 7.9 1.08 .7 28.3 .006 .04 99.9 .1 1.80 5.1 10.9 .370 .29 91.8 8.2 1.09 .7 27.3 .008 .04 99.8 .2 1.82 5.2 10.7 .384 .29 91.5 8.5 1.10 .8 26.4 .010 .05 99.8 .2 1.84 5.3 10.6 .398 .30 91.3 8.7 1.11 .9 24.7 .012 .05 99.7 .3 1.86 5.4 10.4 .412 .30 91.0 9.0 1.12 1.0 24.9 .014 .06 99.7 .3 1.88 5.5 10.3 .426 .31 90.7 9.3 1 13 1.1 24.3 .016 .06 99.6 .4 1.90 5.6 10.2 .440 .31 90.4 9.6 1.14 1.1 23.7 .019 .07 99.6 .4 1.92 5.7 10.0 .454 .32 90.1 9.9 1.15 1.2 23.1 .021 .07 99.5 .5 1.94 5.8 9.9 .468 .32 89.8 10.2 1.16 1.3 22.6 .024 .07 99.5 .5 1.96 5.8 9.8 .483 .32 89.5 10.5 1.17 1.4 22.1 .027 .08 99.4 .6 1.98 5.9 9.7 .497 .33 89.2 10.8 1.18 1.4 21.7 .030 .08 99.3 .7 2.00 6.0 9.5 .512 .33 88.9 11.1 1.19 1.5 21.2 .033 .09 99.2 .8 2.50 8.0 7.4 .881 .43 81.6 18.4 1.20 1.6 20.8 .036 .09 99.2 .8 3.00 9.5 6.0 1.249 .50 75.0 25.0 1.21 1.7 20.4 .039 .10 99.1 .9 3.50 10.9 5.1 1.603 .56 69.1 30.9 1.22 1.7 20.1 .043 .10 99.0 1.0 4.00 12.0 4.4 1.938 .60 64.0 36.0 1.23 1.8 19.7 .046 .10 98.9 1.1 4.50 13.1 3.9 2.255 .64 59.5 40.5 1.24 1.9 19.4 .050 .11 98.9 1.1 5.00 14.0 3.5 2.553 .67 55.6 44.4 1.25 1.9 19.1 .054 .11 98.9 1.2 5.50 14.8 3.2 2.834 .69 52.1 47.9 1.26 2.0 18.8 .058 .12 98.7 1.3 6.00 15.6 2.9 3.100 .71 49.0 51.0 1.27 2.1 18.5 .062 .12 98.6 1.4 6.50 16.3 2.7 3.351 .73 46.2 53.8 1.28 2.1 18.2 .066 .12 98.5 1.5 7.00 16.9 2.5 3.590 .75 43.7 56.2 1.29 2.2 17.9 .070 .13 98.4 1.6 7.50 17.5 2.3 3.817 .76 41.5 58.5 1.30 2.3 17.7 .075 .13 98.3 1.7 8.00 18.1 2.2 4.033 .78 39.5 60.5 1.32 2.4 17.2 .083 .14 98.1 1.9 8.50 18.6 2.1 4.240 .79 37.7 62.3 1.34 2.5 16.8 .093 .15 97.9 2.1 9.00 19.1 1.9 4.437 .80 36.0 64.0 1.36 2.7 16.3 .102 .15 97.7 2.3 9.50 19.6 1.8 4.626 .81 34.5 65.5 1.38 2.8 15.9 .112 .16 97.5 2.5 10.00 20.0 1.7 4.807 .82 33.1 66.9 1.40 2.9 15.6 .122 .17 97.2 2.8 11.00 20.8 1.6 5.149 .83 30.6 69.4 1.42 3.0 15.2 .133 .17 97.0 3.0 12.00 21.6 1.5 5.466 .85 28.4 71.6 1.44 3.2 14.9 .144 .18 96.7 3.3 13.00 22.3 1.3 5.762 .86 26.5 73.5 1.46 3.3 14.6 .155 .19 96.5 3.5 14.00 22.9 1.2 6.040 .87 24.9 75.1 1.48 3.4 14.3 .166 .19 96.3 3.7 15.00 23.5 1.2 6.301 .88 23.4 76.6 1.50 3.5 14.0 .177 .20 96.0 4.0 16.00 24.1 1.1 6.547 .88 22.1 77.9 1.52 3.6 13.7 .189 .21 95.7 4.3 17.00 24.6 1.0 6.780 .89 21.0 79.0 1.54 3.8 13.4 .201 .21 95.5 4.5 18.00 25.1 1.0 7.002 .89 19.9 80.1 1.56 3.9 13.2 .213 .22 95.2 4.8 19.00 25.6 .9 7.212 .90 19.0 81.0 1.58 4.0 13.0 .225 .22 94.9 5.1 20.00 26.0 .9 7.413 .90 18.1 81.9 1.60 4.1 12.7 .238 .23 94.7 5.3 25.00 28.0 .7 8.299 .92 14.8 85.2 1.62 4.2 12.5 .250 .24 94.4 5.6 30.00 29.5 .6 9.035 .94 12.5 87.5 effect of v.s.w.r. on transmitted power v.s.w.r. return trans. volt power power v.s.w.r. loss loss refl. trans refl. db db db coeff. % % v.s.w.r. return trans. volt power power v.s.w.r. loss loss refl. trans refl. db db db coeff. % % frequency designation chart frequency (ghz) ieee std-521-1976 frequency designation jcs frequency designations wavelength (cm) 0.15 0.3 0.5 0.75 1.5 3 5 8 15 30 50 75 300 150 75 50 30 15 7.5 5 3 1.5 0.6 0.4 0.1 0.2 0.4 0.6 1 2 4 6 10 20 40 60 100 200 100 60 40 20 10 6 3.75 2 0.75 0.5 0.3 ab cdefghijklm vhf uhf l s c x ku k ka millimeter sales offices: visit our web site at http://www.temex.net
design aid how to order 15-56 vol. 1 sales offices: visit our web site at http://www.temex.net how to order? 1 isolator 3 3-port circulator 4 4-port circulator 6 differential phase shift circulator for instance: b j 1 0 0 9 - 0 0 x x x x x x - x x technology b coaxial device f waveguide device l, n drop-in device u smd device frequency range using jcs frequency designation ex: j = 10 to 20 ghz model customers part - number 00 catalog reference factory series numbers
ferrite devices quality assurance 15-57 vol. 1 temex quality assurance programme is based on the requirements of iso9001-2000. beyond these requirements, temex de?es ?uality?as customer satisfaction; and to assure that, the temex quality assurance team works closely with engineering and production groups. the company is actively involved in industry task groups concerned with microwave component standards, i.e: electrical measuring methods and test conditions : i.e nfc 96-316 (for microwave devices, circulators and isolators). the high quality of our custom designs is the result of close cooperation between the engineering teams of the customer and those at temex. reproducibility is ensured by rigorous control of all procedures and operations, per mil q 9858a. manufacturing ?w-chart overview quality assurance raw materials incoming inspection pass? storage assembly visual inspection magnetic ?ld adjustment thermal cycling electrical adjustment electrical measurement 100% in line inspection cleaning, painting, marking final inspection pass? request for customer inspection certi?ate of conformance finished products storage packing delivery customer inspection certi?ate of conformance reject reject n n n y y y n sales offices: visit our web site at http://www.temex.net
ferrite devices quality assurance 15-58 vol. 1 sales offices: visit our web site at http://www.temex.net after temperature stabilization, the quality level of delivered models is periodically checked by sampling, according to the tests hereunder and the testing procedures de?ed in the relevant speci?ations. conditions documents 56 7 8 tests nfc iec mil-std k l m n p r s t thermal shocks mechanical shocks sinusoidal vibrations constant acceleration seal damp heat steady state solderability - 25? + 70? 5 cycles - 30 mn 30g 11 ms 3 shocks 3 axes 10 hz 55 hz 10 g 3 axes 5 cycles 15 mn 20 g 3 axes 5 mn method 1 qk test 4 days 40? - 93% soldering heat method tb 260? (1) -40? +85? 5 cycles -30 mn 50g 11 ms 3 shocks 3 axes 10 hz 500 hz 10 g 3 axes 5 cycles 15 mn 50 g 3 axes 5 mn method 2 qc test 10 days 40? - 93% tab termination solderability method ta 235? (2) -40? +100? 5 cycles - 30 mn 100g 6 ms 3 shocks 3 axes 10 hz 2000 hz 10 g 3 axes 5 cycles 20 mn 100 g 3 axes 1 mn not applicable 21 days 40? - 93% not applicable -55? +125? 5 cycles - 30 mn detail sp 10 hz 2000 hz 20 g 3 axes 5 cycles 20 mn 200 g 3 axes 1 mn detail sp detail sp detail sp 20-714 na test nb test 20-727 ea test 20-706 fc test 20-707 ga test 20-717 q test 20-703 ca test 20-720 tb test method 1a ta test method 1 68-2-14 na test nb test 68-2-27 ea test 68-2-6 fc test 68-2-7 ga test 68-2-17 q test 68-2-3 ca test 68-2-20 a (1) 68-2-20 (2) 202 f method 107 f 202 f method 202 d 202 f method 201 a 202 f method 212 a 202 f method 112 c 202 f method 103 b 202 f method 208 f